Menu

Dispensing

with bottle-top dispensers

Functional principle of bottle-top dispensers

By an upward movement of the piston, the preset amount of liquid is aspirated from the reagent bottle into the dispenser cylinder. By the subsequent downward movement of the piston, the liquid is released through a valve system and the discharge tube. There is no need to set a meniscus or to observe a waiting time.

Bottle-top dispensers with floating pistons

Dispensette® from BRAND

Dispensette S

For dispensing aggressive reagents, e.g., concentrated acids such as H3PO4, H2SO4, bases like NaOH, KOH, saline solutions, as well as many organic solvents: Dispensette® S

Dispensette Organic

For dispensing organic solvents, such as chlorinated and fluorinated hydrocarbons (e.g., trichlorotrifluoroethane and dichloromethane), or acids such as concentrated HCl and HNO3, as well as for trifluoroacetic acid (TFA), tetrahydrofuran (THF) and peroxides: Dispensette® S Organic

Dispensette S TA

For dispensing HF we recommend the use of the Dispensette® S Trace Analysis with a platinum-iridium valve spring.

Dispensette® S, Digital, DE-M, 1-10ml, with recirculation valve

Whether you are dispensing solvents, acids, alkalis or saline solutions – the Dispensette® S bottle-top dispenser makes it easy, safe and efficient.With both the Dispensette® S and Dispensette® S Organic, you will always have the right dispenser at hand for a wide range of media. For efficient volume adjustment, you can choose between digital and analog adjustment, or fixed volume. Do you dispense long series, sterile applications or moisture-sensitive media? With numerous accessory options, the Dispensette® S also offers efficient solutions for special applications. Dispensette® S (red color-code): Ideal for dispensing aggressive reagents, including concentrated bases and acids such as H3PO4, H2SO4 (except e.g., HCl, HNO3 und HF), saline solutions, as well as many organic solvents. Digital design: Especially easy to read digital display. The selected dosed volume can be adjusted precisely and is easy to reproduce. Easy calibration technology for adjustment in seconds without tools. Automatic designation if factory default changed. Limitations of use: Operating temperature from +15 °C to +40 °C (from 59 °F to 104 °F) of instrument and reagent Vapor pressure up to max. 600 mbar. Aspirate slowly above 300 mbar, in order to prevent the liquid from boiling Kinematic viscosity up to 500 mm² /s (dynamic viscosity [mPas] = kinematic viscosity [mm² /s] x density [g/cm³) Density up to 2.2

view product

Dispensette® S, Analog-adjustable, DE-M, 0.1-1ml, without recirculation valve

Whether you are dispensing solvents, acids, alkalis or saline solutions – the Dispensette® S bottle-top dispenser makes it easy, safe and efficient.With both the Dispensette® S and Dispensette® S Organic, you will always have the right dispenser at hand for a wide range of media. For efficient volume adjustment, you can choose between digital and analog adjustment, or fixed volume. Do you dispense long series, sterile applications or moisture-sensitive media? With numerous accessory options, the Dispensette® S also offers efficient solutions for special applications. Dispensette® S (red color-code): Ideal for dispensing aggressive reagents, including concentrated bases and acids such as H3PO4, H2SO4 (except e.g., HCl, HNO3 und HF), saline solutions, as well as many organic solvents. Analog-adjustable Model: Rapid and safe volume setting with new internal scalloped track. Simple calibration adjustment with a supplied tool. Limitations of use: Operating temperature from +15 °C to +40 °C (from 59 °F to 104 °F) of instrument and reagent Vapor pressure up to max. 600 mbar. Aspirate slowly above 300 mbar, in order to prevent the liquid from boiling Kinematic viscosity up to 500 mm² /s (dynamic viscosity [mPas] = kinematic viscosity [mm² /s] x density [g/cm³) Density up to 2.2

view product

Dispensette® S Organic, Digital, DE-M, 1-10ml, with recirculation valve

Whether you are dispensing solvents, acids, alkalis or saline solutions – the Dispensette® S bottle-top dispenser makes it easy, safe and efficient.With both the Dispensette® S and Dispensette® S Organic, you will always have the right dispenser at hand for a wide range of media. For efficient volume adjustment, you can choose between digital and analog adjustment, or fixed volume. Do you dispense long series, sterile applications or moisture-sensitive media? With numerous accessory options, the Dispensette® S also offers efficient solutions for special applications. Dispensette® S Organic (yellow color-code): Ideal for dispensing organic solvents, including chlorinated and fluorinated hydrocarbons (e.g., trichlorofluoroethane and dichlormethane), acids like concentrated HCl and HNO3 (except HF), trifluoroacetic acid (TFA), tetrahydrofuran (THF) and peroxides. Digital design: Especially easy to read digital display. The selected dosed volume can be adjusted precisely and is easy to reproduce. Easy calibration technology for adjustment in seconds without tools. Automatic designation if factory default changed. Limitations of use: Operating temperature from +15 °C to +40 °C (from 59 °F to 104 °F) of instrument and reagent Vapor pressure up to max. 600 mbar. Aspirate slowly above 300 mbar, in order to prevent the liquid from boiling Kinematic viscosity up to 500 mm² /s (dynamic viscosity [mPas] = kinematic viscosity [mm² /s] x density [g/cm³) Density up to 2.2

view product

Dispensette® S Trace Analysis, DE-M, PT/IR, 1-10 ml, with recirculation valve

The Dispensette® S Trace Analysis provides outstanding performance for precise volume dispensing of high-purity media for trace analysis. Also suitable for HF with platinum-iridium valve spring. Plastics in contact with media consist of high-purity materials such as PTFE, ETFE, FEP, and PFA. The purest sapphire is used for replaceable valves. Depending on the application, platinum-iridium or tantalum are available as spring materials. A field-tested cleaning process before use in trace analysis is described in the operating manual. If contamination of the bottle contents must be avoided, we recommend using the device without the recirculation valve. The 45 mm standard thread plus the included adapters fit most common lab bottles. The valve block can be rotated 360° so that the bottle label always faces the user for safety. Telescoping filling tube adjusts to different bottle sizes. Easy disassembly for replacement of the dispensing cartridge.

view product

Bottle-top dispensers with wiping-seal piston

seripettor® from BRAND

The design of the system allows a replacement of the complete dispensing cartridge. The somewhat higher operating forces dur-ing filling are minimized by a spring with automatic lifting action. The present example reflects a competitively-priced dispenser for simple dispensing tasks in the volume range of 0.2 to 25 ml.

 

Range of application and materials

 

The range of application in-cludes the daily routine dispens-ing of bases, acids in low con-centration, biological buffers, cell culture media, biological detergents and polar solvents.

The seripettor® pro dispenser is suitable for dispensing acids such as concentrated HCl, po-lar solvents (e.g., acetone) and UV-sensitive media. In contrast to the seripettor® dispenser, valves made from chemically resistant materials are used in this instrument.

seripettor®, 1-10 ml

seripettor® and seripettor® pro are innovative bottle-top dispensers from BRAND with a special design. A lifting spring provides automatic filling. When the piston seal is worn out, the entire dispensing unit can be exchanged by the user quickly and easily. Operating range: seripettor® : Aqueous solutions: Routinely used biological buffer solutions and detergents, antifoaming agents, culture media, vitamin solutions and so on can be dispensed. Hydrogen peroxide can also be dispensed. Agar culture media can be dispensed at up to a max. of 60 °C. Acids: Weak, dilute or non-oxidizing acids can be dispensed. Alkaline solutions: The components of the instrument are compatible with alkaline solutions, such as NaOH, KOH and ammonia. Polar solvents: e.g., polar solvents such as ethanol, methanol, acetylacetone, etc. Limitations of use: Use between +15°C and +40°C of instrument and reagent (seripettor®: agar culture medium up to max. 60 °C) Vapor pressure up to 500 mbar Density up to 2.2 g/cm³ Kinematic viscosity*: 2 ml instrument: 300 mm² /s; 10 ml instrument: 150 mm² /s; 25 ml instrument: 75 mm² /s. * dynamic viscosity [mPas] = kinematic viscosity [mm² /s] x density

view product

seripettor® pro, 0.2-2 ml

seripettor® and seripettor® pro are innovative bottle-top dispensers from BRAND with a special design. A lifting spring provides automatic filling. When the piston seal is worn out, the entire dispensing unit can be exchanged by the user quickly and easily. Uses of seripettor® pro: Aqueous solutions: Biological buffer solutions and detergents, anti-foaming agents, culture media, vitamin solutions, etc. can be dosed in everyday routines. Lyes: such as NaOH, KOH and ammonia. Polar solvents: polar solvents such as ethanol, methanol, acetylacetone, Acetone etc. Acids: such as concentrated HCI, glacial acetic acid. UV-sensitive media Limitations of use: Use between +15°C and +40°C of instrument and reagent (seripettor®: agar culture medium up to max. 60 °C) Vapor pressure up to 500 mbar Density up to 2.2 g/cm³ Kinematic viscosity*: 2 ml instrument: 300 mm² /s; 10 ml instrument: 150 mm² /s; 25 ml instrument: 75 mm² /s. * dynamic viscosity [mPas] = kinematic viscosity [mm² /s] x density

view product

Documents download

Dispensette®

Testing instructions (SOP) | pdf | 681 KB

Dispensette® S

Operating Manual | pdf | 13 MB

Dispensette® S

Brochure | pdf | 1 MB

Dispensette® S

Selection chart | pdf | 33 KB

Dispensette® S - Care and use

Videos | mp4 | 25 MB

Dispensette® S - serial dispensing

Videos | mp4 | 27 MB

Dispensette® S - Thread adapters

Videos | mp4 | 26 MB

Dispensette® S Accessories

Videos | mp4 | 6 MB

Dispensette® S Cleaning

Videos | mp4 | 42 MB

Dispensette® S Introduction

Videos | mp4 | 3 MB

Dispensette® S Start up

Videos | mp4 | 19 MB

Flask adapter

Selection chart | pdf | 442 KB

Liquid Handling with Bottle-Top Instruments

Application Note | pdf | 734 KB

Documents download

Air displacement pipette or repetitive pipette?

Application Note | pdf | 1 MB

HandyStep® touch

Operating Manual | pdf | 6 MB

HandyStep® touch

Brochure | pdf | 2 MB

HandyStep® touch

Selection chart | pdf | 367 KB

HandyStep® touch - auto dispensing

Videos | mp4 | 9 MB

HandyStep® touch - multi dispensing

Videos | mp4 | 8 MB

HandyStep® touch - pipetting modes

Videos | mp4 | 6 MB

HandyStep® touch - safe dispensing

Videos | mp4 | 6 MB

HandyStep® touch with PD-Tips II Accuracy table

Selection chart | pdf | 83 KB

HandyStep® touch/HandyStep® electronic/HandyStep® S

Testing instructions (SOP) | pdf | 1 MB

PD-Tip Adapter

Videos | mp4 | 14 MB

Repetitive pipette HandyStep® touch

Videos | mp4 | 7 MB

Volumetric Measurement

Brochure | pdf | 4 MB

HandyStep® touch

Brochure | pdf | 2 MB

HandyStep® touch with PD-Tips II Accuracy table

Selection chart | pdf | 83 KB

Safety always comes first!

When choosing a bottle-top dispenser, the safety features of the instrument should be kept in mind. For example, does it reduce the risk of injury due to glass breakage? How does it avoid accidental splashing when the instrument is primed? How is contact with the medium minimized when the dispensing tube is closed? Likewise, the suitability of the dispenser for the medium to be dispensed should be checked by the user. Information about this can generally be found in the operating manual in the chapter 'Function and limitations of use'. When in doubt, contact the manufacturer directly. Information on maintenance and monitoring of measuring instruments are also found in the operating manual.

Captcha image

By submitting the contact form, you agree to the processing of your data for the purpose of answering your request (Further information and information on revocation and objection can be found in our privacy statement).

Fields marked with * are required.